Сontrol unit Checkfire 110/210
The fire detection and extinguishing system ANSUL CHECKFIRE 110/210 is designed for use in extreme conditions. This versatile system is purposed to provide fire detection, alarm and extinguishing agent application for mobile equipment such as hydraulic excavators, mining trucks, wheel loaders, bulldozers and graders. The system CHECKFIRE 110/210 is typically used with different fire extinguishing systems: an ANSUL A-101, LVS, or two-component (A-101/ LVS) system for vehicles, to provide 24/7 equipment protection.
- Approved by Factory Mutual (FM);
- Various options for fire detection and extinguishing;
- Circuit monitoring system with automatic configuration;
- Design for extreme environmental conditions;
- Protection against dust and water (protection class IP67);
- Adjustable time delay of the fire extinguishing system;
- Automatic or manual activation;
- Internal emergency power supply;
- Downloadable event log with an ability to record more than 4000 events with a real time stamp;
- System isolation function;
- EAC certification.
Purpose
The system of fire detection and fire extinguishing activation CHECKFIRE 110/210 is used as standard with the fire extinguishing system ANSUL A-101 or LVS designed for vehicles with the purpose to provide 24/7 equipment protection. This system is designed for vehicles and equipment operating in extreme environmental conditions.
Description
The automatic detection and fire extinguishing system CHECKFIRE 110 is equipped with input/output circuit monitoring mechanisms that activate the fire extinguishing system ANSUL. When a fire is detected, the control module activates the fire extinguishing activation circuit, which causes the extinguishing agent to be released from the tank and then sprayed to suppress the fire.
The system components include the control module, sensors for heat spot detection, linear detection sensors, electromechanical actuators, continuous starter, electro-pneumatic actuators, as well as power cables, detection system cables, and cables for the system activation. This complete system is an electrical equipment designed to monitor, communicate and control the components of the A-101 system.
The automatic detection and fire extinguishing system CHECKFIRE 110 is equipped with input/output circuit monitoring mechanisms that activate the fire extinguishing system ANSUL. When a fire is detected, the distribution block initiates a circuit of fire extinguishing activation, which causes the extinguishing agent to be released from the tank and then sprayed to suppress the fire.
LED indicators of green, yellow and/or red color, as well as an internal buzzer indicate the system status. The buzzer is activated only in the case of an error, activation of isolation mode and system operation.
The system components include a display module, a distribution block, and sensors for detecting heat spot, a detection line cable, electromechanical actuators, a continuous actuator, electro-pneumatic actuators, and cables for power circuit, a detection system circuit and an activation system circuit. This complete system is electrical equipment designed to monitor, communicate and control the components of the A-101 system.
Write to us
Our managers will answer you as soon as possible.
This site uses cookies to store data. By continuing to use the site, you consent to work with these files.